SUP23T OPERATIONAL USE 3
Jun 15, 2025
Leave a message
Terminal block diagram of the controller
Figure 2. 1 Terminal block diagram of the controller
Note: The ground wire of the switch power supply must be effectively grounded!
|
Figure 2. 1 Terminal block diagram of the controller Note: The ground wire of the switch power supply must be effectively grounded!
End was compared with the + 24VswitchingMode power supply
To connect to G N D · The switching power supply shell must |
|
be connected tothe earth, otherwise there maybeno li |
etc
unusual.
Optical fiber input port
SUP welding head is suitable for the vast majority of
industrial laser generators, commonly used optical fiber joints
including IPG, Ru ike, Chuangxin, Feibo, Spurs, Jept, Kaplin, etc. Optical devices must be kept clean, in use.
All dust must be removed before and the torch head must be placed horizontally during.
2.4 Protective gas and water cooling machine interface
The water pipe and gas pipe interface can be installed with a hose with outer diameter 6mm inner diameter 4mm. Access and exit pipeline of waterway (regardless of entry and exit direction)
The cooling system is divided into waterway section of welding head and waterway section of optical fiber head connected in series as
shown in the following figure :

2.5 Connection interface between welding gun and control box
The handheld welding head is connected to the control box
through a group of "multi-function system connecting lines". The
handheld welding head end is the aviation plug female head, and the control box head end is the aviation plug male head. The seven-core wire connecting gun body controls the light and temperature
monitoring, and the two-core and five-core wires are the vibrator motor control line.
3. control panel operation guide
The SUP-23T is V 5.8-800-580 and you can view the system version through the monitoring page.
|
famili ar style the Chines e langua ge |
Englis h |
Korean |
Russia n |
comp le x font the Chines e langua ge |
Japane se |
Dervin |
French |
The meanin g is big Leveen |
Monast ery and Site of the Escuri al of Madrid The tooth articl e |
|
grape |
Soil |
Greece |
Chech |
Slowe |
Poland |
Thai |
Vietna |
Roman |
|
|
The |
ear |
Articl |
Articl |
The |
Articl |
m |
Nia |
||
|
tooth |
Its |
e |
e |
vark |
e |
Articl |
Articl |
||
|
articl e |
articl |
Articl |
e |
e |
① This interface can see the current process parameters (this page can not be modified process) and real-time alarm
information.
② The default is ON, the red light is LINE by default, and the
welding mode is continuous. When enabling is turned off, the enabling signal will not be sent to the laser and can be used to test the vent function. Close the red light indicator, the motor stops swinging, and the red light is a point to adjust the center position. The welding
mode is divided into continuous and spot welding. When selecting
spot welding, the spot welding type needs to be set on the setting page.
③ The safety lock is divided into gray and green. When the
metal clip is clamped on the processing piece and the copper nozzle of the gun contacts the processing piece, the 5 and 6 feet of the
signal interface 1 are on, and the safety lock indicator light is green, and press the trigger
The machine can achieve the light.
④ Click on the upper right corner to switch to the cleaning mode.
The current process page provides 10 process items for users to save parameters. The definition and scope of process parameters are described below :
① The process interface contains the process parameters of
debugging, click the box (red) to modify, click OK, and then save in the quick process, click import (modify-save-import).
② The scan speed range is 2-6000mm / S, and the scan width range is 0 ^ 6mm. The scan speed is limited by the scan width, which is : 10
scan speed / (scan width * 2) 1000 If the limit is exceeded, it
automatically becomes the limit value. When the scan width is set to 0, it does not scan (ie, a point light source)
(The most commonly used scanning speed : 300mm / S, width of 2.5-4mm).
③ The peak power should be less than or equal to the laser power of the parameter page (if the laser power is 1000W, this value is not
higher than 1000).
④ Duty cycle range 0 to 100 (default 100, usually not changed).
⑤ The pulse frequency range is recommended from 5-5000Hz (default 2000, usually no modification).
⑥ Click the HELP button on the top right to get more relevant parameter explanations.
⑦ After modifying the parameters, you can see whether the import is successful on the home page
⑧ Reference process, can be used in the small program process reference
① Some lasers cannot emit light with less than 10% power. When the peak power of the process page is less than 10% of the maximum power of the laser on the set page, all output signals are normal, but they may not emit light.
② The duty cycle is 100%, usually does not need to change, when the pulse frequency does not work. If you need to use it, please
adjust it according to the actual requirements. Example : Peak power of 300W, duty cycle of 50%, and pulse frequency of 1000Hz. At this
time, the light cycle is 1 mS, 0.5 mS light is 300W, 0.5 mS is not light, and the cycle continues. At this time, the air at the
welding burst, abnormal sound is normal phenomenon. The actual situation is based to the laser parameters.
③ Click on the Help button on the top right of the screen to get more relevant parameters.
④ More reference process, can be viewed in the WeChat small program process.
Click Settings on the home page to enter on the pass,woCradn entreyr
page of the pop-up window pa.
① The laser power is the power of the used laser, please fill in correctly.
② The default switching air delay is 200ms, ranging from 0 ms to 3000 ms.
③ N 1% of process power to 100%, 1% of process power 100%, progressive to N2 ; (as shown in the figure below):

Generally preset switch light power 20%, switch light gradual time 200ms ;
④ Silk delay compensation is the advance time relative to the light signal, which can be used with the withdrawal function, not set by default ;
⑤ The maximum value of the three temperature alarm valves is 70℃. When the value is set to 0, the temperature is not detected, and the
buzzer alarms when the measured temperature is greater than the set value ;
⑥ Scan correction coefficient = target line width / measured line width, range from 0.01 to 4. Generally set to 1 ;
⑦ Laser center offset-3~3mm, decrease to the left, increase to the right, applied to adjust the axis red light center ;
⑧ The alarm level signal of the air pressure / water cooler / laser is low level by default. When this alarm signal is used, the alarm level here should be set to the same as the alarm level of
the external equipment ;
⑨ The duration of spot welding is the light time in each cycle in the spot welding mode, and the spot welding interval is spot welding
Stop time in each cycle in the mode ;
⑩ Click on the Help button on the top right to get more relevant parameter explanations
This page displays the status of each signal and the equipment information.
① Input signal status
Laser trigger signal : when the user externally controls the 7 and 8 feet of the signal interface 1, this state is changed from gray to green.
Safety lock signal : normal short contact, this state from gray to green effective.
Laser / water cooler / air pressure alarm signal : monitor the real-time level status of these interface inputs.

Figure 3.1-6 Monitoring page-Input signal status bar
② Output signal status
When the signal is output, the signal in this area changes
immediately and can be directly visualized. The monitoring signal is the circuit signal detected in real time, which will fluctuate
in a certain range and have an error of less than 0.3V with the final output signal.

③ Basic information of the equipment
Equipment authorization : click to encrypt the use time of the device. When the device is used for more than the set time, the
authorization will be terminated and the system will stop working. Factory default is long-term effective, if you need encryption and decryption, please contact us for inquiry.
System version : three groups of numbers, the first group is the hardware version, the second group is the single-chip microcomputer program version, the third group is the touch screen version.

④ power status
The real-time power supply voltage and current of the device are shown. Due to the update of the algorithm, the data accuracy
continues to indicate that there will be some differences in
different versions of different versions, which is a normal
phenomenon. Mainly through the power voltage to help after-sales power troubleshooting.

⑤ communication status
"Communication status" indicates the communication between the
touch screen and the motherboard. If not synchronized, check the screen cable.
"Anti-shake" is used to deal with poor contact with safe locks,
which range from 0 to 300 ms. Click "Device authorization Box" to set the parameter range on the password page, as shown in Figure 3.9. The password is "ffffffaa 300", where "ffffffaa" indicates the lock anti- shake parameter and cannot be changed. "300" means 300ms. The effect is that when the trigger signal is normal and the disconnection time of the safety lock signal is <300ms. Material welding used to deal
with poor surface performance and unstable conductivity (e. g. rust) is usually set to 0.
"Motor driver temperature" "Protective mirror temperature"
indicates the two partially measured real-time temperature, " Motor drive
Device temperature " affects the swing performance of the motor, if the environmental heat dissipation of the equipment is not good, the temperature abnormal rise.
High, affect the laser scanning speed, and then lead to the decrease of the weld quality. The lens temperature reflects the working state of
the lens to help determine whether the lens is damaged.

⑥ diagnose
Click the diagnostic button to enter the diagnostic interface. Use to measure whether the signal port has an actual output, usually the output value is consistent with the detection value. When
inconsistent, the load is abnormal, such as when the laser does not light, through the single port with the laser monitoring software or multimeter measurement, can be the real reaction signal
issue.
Indicate the red light to switch to "point", replace the cutting nozzle. Cutting control logic is the same as welding, need to press the trigger while the safety lock conduction.
