SUP 23T Laser head 3
Jun 18, 2025
Leave a message
② The default state is ON, indicating that the red light is LINE by default. When enabling is turned off, the enabling signal will
not be sent to the laser and can be used to test the vent function. Close the red light indication, the motor stops swinging, and the
red light is a point to adjust the center position.
③ Click on the upper right corner to switch to the cleaning mode.

① The process interface contains the process parameters of
debugging, click the box (red) to modify, click OK, and then save in the quick process, click import (modify-save-import).
② The scan frequency range is 10100 HZ, and the scan width range is 0 ^ 30mm.
(At the focusing lens F800, the maximum width is 130mm. At the
focusing mirror F150, the maximum width is 30mm).③ Peak power
should be less than or equal to the parameter page laser power. (If the laser power is 1000W, then this value is not higher than 1000).
④ Duty cycle range 0 to 100 (default 100, usually not changed).
⑤ The pulse frequency range is recommended from 5-5000Hz (default 2000, usually not changed).
⑥ Click the "Help" button on the top right to get more relevant parameters.
⑦ After modifying the parameters, you can see whether the import is successful on the home page.
⑧ Reference process, can be used in the small program process reference.

Password: 123456
① The laser power is the power of the used laser, please fill in correctly.
② The default gas delay default 200ms, range 200ms-3000ms.
③ From N 1% of process power to 100% ; from 100% of process power to N2 ; (as shown in the figure below).

The higher the process power, the lower the recommended open
light power. The open light power usually should not exceed 50%, too high open light power will greatly reduce the service life of the lens.
④ The maximum temperature alarm valve value is 65℃. When the value is set to 0, the temperature alarm is not detected.
⑤ Scan correction coefficient range 0.01~4, coefficient target line width / measured line width : the default is 1.0.
⑥ Laser center offset-75~75mm, reduced to the left, increased to the right, applied to adjust the red light center
⑦ The pressure / water cooler / laser alarm level signal is low
level by default. When this alarm signal is used, if the external
pressure alarm is installed, it will be changed to high level,
otherwise abnormal alarm will appear, and other alarm signals should be the same.
⑧ Click the "Language" button, you can switch to other languages in the language selection bar. Currently, the standard version
supports 19 languages. Please contact us if necessary.

⑨ Click "Help" in the upper right corner to enter the help page of the Settings page. Long press "Restore factory Settings" to restore the setting parameters to the factory state. Long press "Save as
factory settings" to modify the factory parameters.
⑩ Click "Gun size number" to focus the mirror to select the maximum scanning width.

This page displays the status of each signal and the equipment information
Laser trigger signal : when the trigger is pulled, this state changes from gray to green
Laser / water cooler / air pressure alarm signal : monitor the high and low levels
The output signal is shown in the middle of the page, colored green when the signal is output
Equipment authorization : the equipment can be authorized, when the equipment is used over the set time, the authorization shall be
terminated,
System version : three groups of numbers, the first group is the
hardware version, the second group is the single-chip microcomputer program version, the third group is the touch screen version

Click the Diagnostic sbutton to enter the diagnostic page. Under this page, the laser will not emit light, and can independently output "PWM", "laser enabling", "air valve enabling", "analog"
through "switch control", to judge whether the control box detection and theoretical value function is normal.
Maintenance and replacement method of related lenses :
① Before operation, please clean your hands and dry them, and then wipe them with cotton and alcohol again.
② Open the protective mirror in a relatively dust-free place, focus the mirror compartment cover, pull out the lens bracket,
do a good job of protection (beautiful paper cover), check the protective lens, if there is an obvious burning point on the
lens surface, should be directly replaced.
③ Then check the white storage seal ring under the lens. (If the storage sealing ring cannot be used, it must be replaced immediately.
④ Wipe the warehouse mouth and the inside of the warehouse cover with a cotton ball dipped in alcohol, quickly insert the protective lens bracket into the protective mirror compartment, and lock the
screws.
5. common exception handling
Prompt laser/water cooler/air pressure alarm
① If the above alarm does not using the alarm signal, please change the alarm level of screen setting page.
② If the alarm signal appears in the above alarm, check the alarm or alarm signal of the corresponding equipment
Whether the high and low level is set correctly.
5.2 The screen is not lit and there is no response when clicking
① The screen is not bright, make sure that the controller is electrified. Check whether the controller and the four-core wire of the screen are connected correctly, and whether the voltage of the 1st foot and the 4th foot 24V is normal.
② If not clicked in normal use, check whether the temperature of the machine is too high.
③ Click unable to input, check whether the wiring between the
controller and the screen is correct, and whether the second and third feet are normal. See 2. 1.2 controller display end for details.
④ Newly installed device click no response may be the system version does not match, use the SD card to rebrush the program
Yes, please ask us for the specific version.
5.3 No light
① Check whether there is an alarm prompt on the home page, and whether the laser enabling system is ON ;
② Check whether the trigger signal and safety lock signal of the monitoring page are displayed in green during welding ;
③ Check whether the PWM, laser enabling and analog output of the monitoring page are normal during welding. If the above conditions are normal, check the laser forabnormal alarm.
Example : the air supply wire but not the light, for the laser fault or laser wiring error. If neither air
It may be missing input signal, see : 2. 1.3 Controller signal interface 1.
5.4 The light suddenly stops during processing
Check whether the safety ground lock and other alarm of the monitoring interface are normal.
Laser welding machine three-phase power supply connection reference:
Note : Two-phase or three-phase electricity depends on the power supply required by the laser and the chiller, rather than the
amount of wire harness.