Chapter IV Maintenance
4.1 Structure of optics lens
※ The assembly is completed in the dust-free plant at the time of replacement of parts. In principle, except for the front-end first protective glass can be disassembled and assembled, other modules are forbidden to be dismounted. If it is necessary to check the collimation lens, focus lens and galvanometer lens, the product shall be put into a clean environment for disassembly.

4.2 Cleaning of optics lens
※ When the optics lens are cleaned, the operation method and attention points are as follows:
※ Tools: dust-free gloves or dust-free fingerstall, dust-free wiping cotton swab, isopropyl alcohol, and caned dry and pure compressed air.
※ Spray the isopropyl alcohol onto the dust-free cotton swab, align the lens to eyes, gently pinch the side edge of the lens with left thumb and index finger and hold the dust-free cotton swab with right hand to gently wipe the front and back of the lens in a single direction from bottom to top or from left to right (avoid wiping back and forth to avert the secondary contamination of lens), blow the surface of the lens with filling dry and pure compressed air and confirm the surface of lens is free from foreign matters after cleaning.

4.3 Disassembly and assembly of optics lens
4.3.1 Disassembly and assembly of collimation lens
Tool: 2mm inner-hexagon wrench, dust-free cotton swab, alcohol.
※ The disassembly and assembly shall be completed in a clean place. When the lens are dismounted, the dust-free gloves or dust-free fingerstall.
※ Disassembly and assembly steps:
Step 1: Clean up all the dust on the surface of the laser head firstly.
Step 2: Loosen the 4-M2.5*6 screw in the figure with 2mm inner-hexagon wrench.
Step 3: Take out the collimating drawer module and seal the port with textured paper to prevent the dust from entering the cavity. Step 4: When the two bosses are aligned with the opening slot after the gland is rotated anticlockwise, remove them upward and replace the lens. (Note that the orientation of lens installation can be divided into plane and convex surface. After disassembly, record it; otherwise, the optical path will be affected.)

4.3.2 Disassembly and assembly of focus lens
Tool: 2mm inner-hexagon wrench, dust-free cotton swab, alcohol
※ The disassembly and assembly shall be completed in a clean place. When the lens are dismounted, the dust-free gloves or dust-free fingerstall.
※ Disassembly and assembly steps:
Step 1: (figure 1) Loosen the lateral 2-M2.5 screws.
Step 2 : Remove the focus drawer assembly horizontally and seal the exposed sealing surface of the cavity with textured paper to prevent dust from entering.
Step 3: (figure 2) When the two bosses are aligned with the opening slot after the gland is rotated anticlockwise, remove them upward and replace the lens. (Note that the orientation of lens installation can be divided into plane and convex surface. After disassembly, record it; otherwise, the optical path will be affected.)

4.3.3 Disassembly and assembly of protective glass
※ The disassembly and assembly shall be completed in a clean place. When the lens are dismounted, the dust-free gloves or dust-free fingerstall.
Change the protective lens
The first step is to take both sides of the drawer in hand and pull out the protective drawer seat upward. After taking it out, seal the window exposed on the cavity with textured paper to prevent dust from entering.
Step 2,
When the two bosses are aligned with the opening slot after the gland is rotated anticlockwise, remove them upward and replace the lens.

5.1 Installation Dimension Drawing for Product
5.1.1 Installation dimension of touch screen
External dimension (209.5*150*24)mm
The installation dimension of the touch screen is shown in the following figure:

5.1.2 Installation dimension of mainboard