Chapter VII Introduction To HMI Operation

7.1 Introduction to HMI function

As for the handheld laser welding system operation panel (hereinafter referred to as "HMI"), the 7cun configuration TFT touch screen is used, with beautiful interface and convenient operation. The laser-related parameters can be set, respectively and

the real-time display of input/output IO state, alarm information and running state can be realized on the main interface.

Refer to the following figure for the HMI main interface.

 

Main interface of HMI

info-868-517

[Bluetooth mark]: Display whether the bluetooth matching connection between the equipment and the mobile terminal is conducted.

[Scanning parameter]: Used to set the parameters related to the scanning processing of the galvanometer.

Parameter No: Multiple groups of different cleaning parameters can be set with different parameter numbers.

Scanning speed: It is used to set the scanning speed of the galvanometer.

 

Laser power: It is used to set the percentage of the peak power of the laser.

Laser frequency: It is used to set the PWM frequency of the laser.

Duty ratio: It is used to set PWM signal duty ratio of continuous laser.

Scanning length: It is used to set the length of the laser scan.

[System Settings]: Click to enter the system setting page and modify system function parameters. [Alarm State Area]: After the alarm signal is enabled, the real-time display of protective gas undervoltage alarm, cold water flow alarm, laser alarm and temperature alarm, and galvanometer state is conducted. The real-time display of safety lock state will arise when the safety lock is enabled; When the alarm signal isn't triggered, the corresponding alarm state will turn into blue; When the alarm occurs, the corresponding alarm icon will flicker between red light and blue light. [Red light | switch on/off]: The red light switch can control the switch of the laser red light indication.

 

[preparation \ stop | cleaning]: Emission of laser can be allowed or forbidden by the button. In a state ready to clean, press the cleaning start button will be laser cleaning; Under the stop cleaning state, press the cleaning start button will not produce light cleaning.

 

7.2 System parameter setting

System parameter setting, The modification takes effect after being saved.

Double click light extraction enabling: Switch off the enabling function. Click the button once and the laser will come out. Switch on the enabling function. Double click the button twice and the laser will come out.

Air release delay: Delay in enabling gas can be set when processing is enabled. The emission of laser will start after blowing is delayed for a period of time by pressing the external start button.

Air close delay: Delay in closing gas can be set when processing is stopped. Stop blowing after stopping laser emission, and then delaying for a period of time when processing is stopped.

Scale factor: This parameter is used to set the maximum range of the galvanometer. The value must be consistent with the actual range of the galvanometer; otherwise, the actual length and width of the light output may be inaccurate.

 

Enabling the safety lock: Select whether to enable security lock protection.

[Chinese/2 English]: Switch between Chinese and English languages.

Automatic screen lock: When the automatic screen lock is enabled, the system automatically switches to the screen lock page when no operations are performed on the touchscreen after a period of time.

[Authorization]: Perform authorization code reading and decryption operations, and display the information about the panel and mainboard version numbers.

 

7.3 Equipment parameters

[Equipment parameters]: It is used to limits the maximum and minimum parameters. This parameter limits the laser parameters, only by entering the password to enable it. After the parameter is changed, it must be saved to take effect.

 

Maximum scanning speed: It is used to set the maximum oscillating speed of the galvanometer

 

Minimum scanning speed: It is used to set the minimum oscillating speed of the galvanometer

 

Maximum scanning speed: It is used to set the maximum scanning length allowed by the equipment

 

Minimum scanning speed: It is used to set the minimum scanning length allowed by the equipment

 

Laser rated power: It is used for setting the rated power of the laser.

 

Maximum laser frequency: It is used to set the maximum laser frequency

 

Minimum laser frequency: It is used to set the minimum laser frequency

 

Laser alarm enabling: It is used to set whether to enable laser alarm. If this parameter is enabled, a laser alarm will be generated when the laser alarm input triggers the alarm.

 

Laser alarm electrical level: It is used to set the laser alarm that triggers the electrical level logic.

 

Water-cooling machine alarm enabling: It is used to set whether to enable water-cooling

machine alarm. If this parameter is enabled, a water-cooling machine alarm will be generated when the water-cooling machine alarm input triggers the alarm.

 

Water-cooling machine alarm electrical level: It is used to set the water-cooling machine alarm that triggers the electrical level logic.

 

Undervoltage alarm enabling: It is used to set whether to enable gas undervoltage alarm. If this parameter is enabled, a undervoltage alarm will be generated when the undervoltage alarm input triggers the alarm.

 

Undervoltage alarm level: It is used to set the undervoltage alarm that triggers the electrical level logic.

 

Temperature alarm enabling: It enables the lens temperature alarm. When the temperature exceeds the limit value, an alarm signal will be generated.

 

Temperature alarm limit: Lens temperature limit value.

7.4 Alarm message

Alarm information includes: Safety clamp alarm and machine alarm.

 

Safety clamp alarm lies in that the safety clamp and cleaning head is not reliable conduction.

 

Machine alarm includes 3 alarms, laser alarm, water-cooling machine alarm, undervoltage alarm. In the alarm information interface, it can display multiple alarm information, up to 3 pages, and it can switch through the previous page and the next page.

 

When the alarm is triggered, the output of the laser will be stopped and the galvanometer will stop moving at the same time, and the corresponding alarm information will be prompted. The user can check the related hardware problems according to the alarm prompt and remove the alarm. When the alarm is lifted, the alarm record of the machine alarm will still exist in the alarm information. At this time, you can manually clear the alarm by entering the alarm information interface. If the alarm is not lifted, the alarm will continue to prompt when it is manually cleared.

 

Chapter VIII Processing Module Switching

8.1 Temperature parameter setting of protective glass

[Home Page]→ [System Parameter]→ [Equipment Parameter]→ [Input Password: 666888] →next page→ lens temperature alarm limit value.

It's suggested to set the set value of lens temperature to 50. After the lens temperature exceeds the set value, the alarm caution will arise on the home page and the display light on the side of the handheld plumb joint will turn to red.

 

8.2 Bluetooth APP monitoring

In case of use for the first time, it's necessary to download the Farguard applet which can be used to contact the after-sales customer service personnel. Notes: The APP now only supports the mobile phone with Android operating system. The applet icon is as follows:

 

Monitoring home screen, welding system, cleaning system and selection as per the use category.

The current usage can be viewed by the equipment state page.

 